scispace - formally typeset
Journal ArticleDOI

Spatial registration and normalization of images

TLDR
A general technique that facilitates nonlinear spatial (stereotactic) normalization and image realignment is presented that minimizes the sum of squares between two images following non linear spatial deformations and transformations of the voxel (intensity) values.
Abstract
This paper concerns the spatial and intensity transformations that map one image onto another. We present a general technique that facilitates nonlinear spatial (stereotactic) normalization and image realignment. This technique minimizes the sum of squares between two images following nonlinear spatial deformations and transformations of the voxel (intensity) values. The spatial and intensity transformations are obtained simultaneously, and explicitly, using a least squares solution and a series of linearising devices. The approach is completely noninteractive (automatic), nonlinear, and noniterative. It can be applied in any number of dimensions. Various applications are considered, including the realignment of functional magnetic resonance imaging (MRI) time-series, the linear (affine) and nonlinear spatial normalization of positron emission tomography (PET) and structural MRI images, the coregistration of PET to structural MRI, and, implicitly, the conjoining of PET and MRI to obtain high resolution functional images. © 1995 Wiley-Liss, Inc.

read more

Citations
More filters
Journal ArticleDOI

Automated Anatomical Labeling of Activations in SPM Using a Macroscopic Anatomical Parcellation of the MNI MRI Single-Subject Brain

TL;DR: An anatomical parcellation of the spatially normalized single-subject high-resolution T1 volume provided by the Montreal Neurological Institute was performed and it is believed that this tool is an improvement for the macroscopical labeling of activated area compared to labeling assessed using the Talairach atlas brain.
Journal ArticleDOI

Statistical parametric maps in functional imaging: A general linear approach

TL;DR: In this paper, the authors present a general approach that accommodates most forms of experimental layout and ensuing analysis (designed experiments with fixed effects for factors, covariates and interaction of factors).
Journal ArticleDOI

A global optimisation method for robust affine registration of brain images

TL;DR: It is demonstrated that the use of local optimisation methods together with the standard multi-resolution approach is not sufficient to reliably find the global minimum, so a global optimisation method is proposed that is specifically tailored to this form of registration.
References
More filters
Book

Co-planar stereotaxic atlas of the human brain : 3-dimensional proportional system : an approach to cerebral imaging

TL;DR: Direct and Indirect Radiologic Localization Reference System: Basal Brain Line CA-CP Cerebral Structures in Three-Dimensional Space Practical Examples for the Use of the Atlas in Neuroradiologic Examinations Three- Dimensional Atlas of a Human Brain Nomenclature-Abbreviations Anatomic Index Conclusions.
Journal ArticleDOI

Principal warps: thin-plate splines and the decomposition of deformations

TL;DR: The decomposition of deformations by principal warps is demonstrated and the method is extended to deal with curving edges between landmarks to aid the extraction of features for analysis, comparison, and diagnosis of biological and medical images.
Journal ArticleDOI

Automatic 3D intersubject registration of MR volumetric data in standardized Talairach space

TL;DR: A fully automatic registration method to map volumetric data into stereotaxic space that yields results comparable with those of manually based techniques and therefore does not suffer the drawbacks involved in user intervention.
Journal ArticleDOI

Rapid automated algorithm for aligning and reslicing PET images.

TL;DR: A computer algorithm for the three-dimensional alignment of PET images is described that relies on anatomic information in the images rather than on external fiducial markers and can be applied retrospectively, during acquisition, to reposition the scanner gantry and bed to match an earlier study.
Related Papers (5)