scispace - formally typeset
Search or ask a question
JournalISSN: 1472-6890

BMC Clinical Pathology 

Springer Science+Business Media
About: BMC Clinical Pathology is an academic journal. The journal publishes majorly in the area(s): Cancer & Tissue microarray. It has an ISSN identifier of 1472-6890. Over the lifetime, 282 publications have been published receiving 6967 citations.


Papers
More filters
Journal ArticleDOI
TL;DR: Cardiac puncture appeared to be the fastest and more reliable technique, yielding the maximum blood volume with the least amount of stress being exerted on the sampling site, and that cardiac puncture is the best method of blood collection in mice.
Abstract: Background In many animal models that investigate the pathology of various diseases, there is a need to monitor leukocyte counts and differentials. However, various researchers use a range of different techniques in male and female laboratory animals to collect such blood variable information. These studies are then compared to one another without consideration of the possibility that different bleeding sites or techniques as well as gender may produce varying results. In light of this, the peripheral blood leukocyte counts and differentials of C57BL/6 male and female mice were determined using four blood-sampling techniques: cardiac, tail, foot, and saphenous vein punctures.

212 citations

Journal ArticleDOI
TL;DR: The results indicated that the image information contained in current whole slide images is sufficient for pathologists to make reliable diagnostic decisions and compose complex diagnostic reports, but this does not mean that WSI is as good as a microscope.
Abstract: Only prototypes 5 years ago, high-speed, automated whole slide imaging (WSI) systems (also called digital slide systems, virtual microscopes or wide field imagers) are becoming increasingly capable and robust. Modern devices can capture a slide in 5 minutes at spatial sampling periods of less than 0.5 micron/pixel. The capacity to rapidly digitize large numbers of slides should eventually have a profound, positive impact on pathology. It is important, however, that pathologists validate these systems during development, not only to identify their limitations but to guide their evolution. Three pathologists fully signed out 25 cases representing 31 parts. The laboratory information system was used to simulate real-world sign-out conditions including entering a full diagnostic field and comment (when appropriate) and ordering special stains and recuts. For each case, discrepancies between diagnoses were documented by committee and a "consensus" report was formed and then compared with the microscope-based, sign-out report from the clinical archive. In 17 of 25 cases there were no discrepancies between the individual study pathologist reports. In 8 of the remaining cases, there were 12 discrepancies, including 3 in which image quality could be at least partially implicated. When the WSI consensus diagnoses were compared with the original sign-out diagnoses, no significant discrepancies were found. Full text of the pathologist reports, the WSI consensus diagnoses, and the original sign-out diagnoses are available as an attachment to this publication. The results indicated that the image information contained in current whole slide images is sufficient for pathologists to make reliable diagnostic decisions and compose complex diagnostic reports. This is a very positive result; however, this does not mean that WSI is as good as a microscope. Virtually every slide had focal areas in which image quality (focus and dynamic range) was less than perfect. In some cases, there was evidence of over-compression and regions made "soft" by less than perfect focus. We expect systems will continue to get better, image quality and speed will continue to improve, but that further validation studies will be needed to guide development of this promising technology.

181 citations

Journal ArticleDOI
TL;DR: Findings suggest that measurement of cortisol in hair could serve as a retrospective biomarker of increased cortisol production reflecting exposure to major life stressors and possibly extended psychological illness with important implications for research, clinical practice and public health.
Abstract: Stress as a cause of illness has been firmly established. In public health and stress research a retrospective biomarker of extended stress would be an indispensible aid. The objective of this pilot study was to investigate whether concentrations of cortisol in hair correlate with perceived stress, experiences of serious life events, and perceived health in young adults. Hair samples were cut from the posterior vertex area of (n = 99) university students who also answered a questionnaire covering experiences of serious life events, perceived Stress Scale and perceived health during the last three months. Cortisol was measured using a competitive radioimmunoassay in methanol extracts of hair samples frozen in liquid nitrogen and mechanically pulverised. Mean cortisol levels were significantly related to serious life events (p = 0.045), weakly negatively correlated to perceived stress (p = 0.025, r = -0.061) but nor affected by sex, coloured/permed hair, intake of pharmaceuticals or self-reported health. In a multiple regression model, only the indicator of serious life events had an independent (p = 0.041) explanation of increased levels of cortisol in hair. Out of four outliers with extremely high cortisol levels two could be contacted, both reported serious psychological problems. These findings suggest that measurement of cortisol in hair could serve as a retrospective biomarker of increased cortisol production reflecting exposure to major life stressors and possibly extended psychological illness with important implications for research, clinical practice and public health. Experience of serious life events seems to be more important in raising cortisol levels in hair than perceived stress.

177 citations

Journal ArticleDOI
TL;DR: Most mistakes occurred before samples were analysed, either during sampling or preparation for analysis, suggesting that co-operation with clinicians and personnel outside the laboratory is still the key to improvement of laboratory quality.
Abstract: Reliability cannot be achieved in a clinical laboratory through the control of accuracy in the analytical phase of the testing process alone. Indeed a "mistake" can be defined as any defect occuring during the testing process. In the analysis of clinical specimens, there are many possible preanalytical sources of error. Therefore, the application of quality system to laboratory testing requires total quality management throughout the laboratory process, including the preanalytical and postanalytical phases. ISO 9002:1994 is a model for quality assurance in production, installation, and servicing, which includes a number of clauses providing guidance for implementation in clinical laboratories. Our laboratory at King Chulalongkorn Memorial Hospital, the largest Thai Red Cross Society hospital, is the first clinical laboratory in Thailand with ISO 9002:1994 certified for the whole unit. In this study, we evaluated the frequency and types of preanalytical mistakes found in our laboratory, by monitoring specimens requested for laboratory analyses from both in-patient and out-patient divisions for 6 months. Among a total of 935,896 specimens for 941,902 analyses, 1,048 findings were confirmed as preanalytical mistakes; this was a relative frequency of 0.11 % (1,048/935,896). A total of 1,240 mistakes were identified during the study period. Comparing the preanalytical mistakes to other mistakes in the laboratory process monitored in the same setting and period, the distribution of mistakes was: preanalytical 84.52 % (1,048 mistakes), analytical 4.35 % (54 mistakes), and postanalytical 11.13 % (138 mistakes). Of 1,048 preanalytical mistakes, 998 (95.2%) originated in the care units. All preanalytical mistakes, except for 12 (1.15 %) relating to the laboratory barcode reading machine, were due to human error. Most mistakes occurred before samples were analysed, either during sampling or preparation for analysis. This suggests that co-operation with clinicians and personnel outside the laboratory is still the key to improvement of laboratory quality.

154 citations

Journal ArticleDOI
TL;DR: An automated assay to calculate the antioxidant capacity of plasma after a subtraction of all interference deriving from endogenous and/or exogenous metabolites is presented, which can be used as a useful indicator of the antioxidant value of foods and beverages in the daily diet.
Abstract: Antioxidant molecules, which scavenge free radical species to prevent or delay oxidative damage of important macromolecules, membrane lipids and lipoproteins, are prevalent in plasma and other biological fluids. Among them, bilirubin, uric acid and protein thiols are the major endogenous antioxidants, while vitamins C and E, as well as a number of food-derived (poly)aromatic substances, belonging to stilbens, flavonoids and phenolic acids, are the main classes of nutritional antioxidants. Assays for total antioxidant capacity in plasma differ in their type of oxidation source, target and measurement used to detect the oxidized product. In the present work we present an automated assay for the estimation of blood total antioxidant capacity (TAC assay), based on the crocin bleaching (oxidation) method. This method was adapted on a modern autoanalyzer, was linear over a wide range of values (0–3 mmol/L), and performed using an end point measurement. The TAC method presented a linear correlation with another automated commercial Total Antioxidant Status (TAS) test. Detection of the interference of different metabolites revealed a significant participation of TAC from uric acid, bilirubin, albumin, a minor interference from ascorbic acid, and no interference from hemoglobin. TAC was not modified by two freeze/thawing cycles, and was stable in samples stored at room temperature for 4 hours. K-EDTA and heparin were the best anticoagulants, while citrate decreased TAC by 20%. Reference values derived from samples of normal blood donors was 1.175 ± 0.007 mmol/L (mean ± SEM), while a diet rich in antioxidants more than doubled this value. The proposed TAC assay, is fully automated, stable and reliable, and could be of value in the estimation of the AC of plasma. It is further proposed to calculate the antioxidant capacity of plasma after a subtraction of all interference deriving from endogenous and/or exogenous metabolites. The antioxidant capacity of plasma thus calculated can be used as a useful indicator of the antioxidant value of foods and beverages in the daily diet.

146 citations

Network Information
Related Journals (5)
Modern Pathology
6.3K papers, 327.6K citations
80% related
BMC Cancer
15.9K papers, 429.6K citations
80% related
Histopathology
9.1K papers, 304.3K citations
79% related
Archives of Pathology & Laboratory Medicine
11.9K papers, 333.7K citations
79% related
Human Pathology
11.2K papers, 466.3K citations
78% related
Performance
Metrics
No. of papers from the Journal in previous years
YearPapers
20195
201815
201728
201616
201522
201445