scispace - formally typeset
Search or ask a question
JournalISSN: 1522-1946

Catheterization and Cardiovascular Interventions 

Wiley
About: Catheterization and Cardiovascular Interventions is an academic journal published by Wiley. The journal publishes majorly in the area(s): Percutaneous coronary intervention & Stent. It has an ISSN identifier of 1522-1946. Over the lifetime, 10923 publications have been published receiving 183995 citations. The journal is also known as: Catheterization & cardiovascular interventions.


Papers
More filters
Journal ArticleDOI
TL;DR: A primary challenge in the development of clinical practice guidelines is keeping pace with the stream of new data on which recommendations are based as discussed by the authors, and the American College of Cardiology Foundation/American Heart Association (ACCF/AHA) is to respond promptly to new evidence.
Abstract: ### Preamble A primary challenge in the development of clinical practice guidelines is keeping pace with the stream of new data on which recommendations are based. In an effort to respond promptly to new evidence, the American College of Cardiology Foundation/American Heart Association (ACCF/AHA)

1,750 citations

Journal ArticleDOI
TL;DR: WRITING COMMITTEE MEMBERS* Patrick T. O’Gara, MD, FACC, FAHA, Chair†; Frederick G. Kushner,MD, F ACC,FAHA, FSCAI, Vice Chair*†; Deborah D. Kushner-Kushner, PhD, MBA, FACP, FAha‡; Mina K. Linderbaum, MS, CNP-BC.
Abstract: WRITING COMMITTEE MEMBERS* Patrick T. O’Gara, MD, FACC, FAHA, Chair†; Frederick G. Kushner, MD, FACC, FAHA, FSCAI, Vice Chair*†; Deborah D. Ascheim, MD, FACC†; Donald E. Casey, Jr, MD, MPH, MBA, FACP, FAHA‡; Mina K. Chung, MD, FACC, FAHA*†; James A. de Lemos, MD, FACC*†; Steven M. Ettinger, MD, FACC*§; James C. Fang, MD, FACC, FAHA*†; Francis M. Fesmire, MD, FACEP* ¶; Barry A. Franklin, PHD, FAHA†; Christopher B. Granger, MD, FACC, FAHA*†; Harlan M. Krumholz, MD, SM, FACC, FAHA†; Jane A. Linderbaum, MS, CNP-BC†; David A. Morrow, MD, MPH, FACC, FAHA*†; L. Kristin Newby, MD, MHS, FACC, FAHA*†; Joseph P. Ornato, MD, FACC, FAHA, FACP, FACEP†; Narith Ou, PharmD†; Martha J. Radford, MD, FACC, FAHA†; Jacqueline E. Tamis-Holland, MD, FACC†; Carl L. Tommaso, MD, FACC, FAHA, FSCAI#; Cynthia M. Tracy, MD, FACC, FAHA†; Y. Joseph Woo, MD, FACC, FAHA†; David X. Zhao, MD, FACC*†

535 citations

Journal ArticleDOI
TL;DR: The risk of device erosion with ASO is low and complications can be decreased by identifying high‐risk patients and following them closely, as well as identifying high-risk cases, early recognition, and prompt intervention.
Abstract: The objectives of this study were to identify possible risk factors that may lead to erosion of the Amplatzer septal occluder (ASO) and recommend ways to minimize future risk. There have been rare occurrences of adverse events with development of pericardial effusion after ASO placement. Identification of high-risk cases, early recognition, and prompt intervention may minimize the future risks of adverse events. In all patients who developed hemodynamic compromise after ASO placement, echocardiograms (pre-, intra-, and postprocedure), atrial septal defect (ASD) size (nonstretched, stretched), size of the device used, cineangiograms, and operative records were reviewed by a panel selected by AGA Medical Corporation. The findings were compared to the premarket approval data obtained from FDA-approved clinical trials that were conducted in the United States, before the device was approved. A total of 28 cases (14 in United States) of adverse events were reported to AGA Medical. All erosions occurred at the dome of the atria, near the aortic root. Deficient aortic rim was seen in 89% and the defect described as high ASD, suggesting deficient superior rim. The device to unstretched ASD ratio was significantly larger in the adverse event group when compared to the FDA trial group. The incidence of device erosion in the United States was 0.1%. The risk of device erosion with ASO is low and complications can be decreased by identifying high-risk patients and following them closely. Patients with deficient aortic rim and/or superior rim may be at higher risk for device erosion. Oversized ASO may increase the risk of erosion. The defect should not be overstretched during balloon sizing. Patients with small pericardial effusion at 24 hr should have closer follow-up.

507 citations

Journal ArticleDOI
TL;DR: The periprocedure risks for major and minor strokes and death are generally acceptable at this early stage of development and have not changed significantly since the first survey results.
Abstract: The purpose of this article is to review and update the current status of carotid artery stent placement in the world. Surveys to major interventional centers in Europe, North and South America, and Asia were initially completed in June 1997. Subsequent information from these 24 centers in addition to 12 new centers has been obtained to update the information. The survey asked the various questions regarding the patients enrolled, procedure techniques, and results of carotid stenting, including complications and restenosis. The total number of endovascular carotid stent procedures that have been performed worldwide to date included 5,210 procedures involving 4,757 patients. There was a technical success of 98.4% with 5,129 carotid arteries treated. Complications that occurred during the carotid stent placement or within a 30-day period following placement were recorded. Overall, there were 134 transient ischemic attacks (TIAs) for a rate of 2.82%. Based on the total patient population, there were 129 minor strokes with a rate of occurrence of 2.72%. The total number of major strokes was 71 for a rate of 1.49%. There were 41 deaths within a 30-day postprocedure period resulting in a mortality rate of 0.86%. The combined minor and major strokes and procedure-related death rate was 5.07%. Restenosis rates of carotid stenting have been 1.99% and 3.46% at 6 and 12 months, respectively. The rate of neurologic events after stent placement has been 1.42% at 6-12-month follow-up. Endovascular stent treatment of carotid artery atherosclerotic disease is growing as an alternative for vascular surgery, especially for patients that are high risk for standard carotid endarterectomy. The periprocedure risks for major and minor strokes and death are generally acceptable at this early stage of development and have not changed significantly since the first survey results. Cathet. Cardiovasc. Intervent. 50:160-167, 2000.

495 citations

Journal ArticleDOI
TL;DR: The periprocedure risks for major and minor strokes and death are generally acceptable at this early stage of development and have shown an improvement with technological developments, including distal embolic protection.
Abstract: The purpose of this article was to review and update the current status of carotid artery stent placement in the world. Surveys of major interventional centers in Europe, North and South America, and Asia were initially completed in June 1997. Subsequent updates from these 24 centers in addition to 29 new centers have been obtained to bring up to date the information. The survey asked the various questions regarding the patients enrolled, procedure techniques, and results of carotid stenting, including complications and restenosis. The total number of endovascular carotid stent procedures that have been performed worldwide to date included 12,392 procedures involving 11,243 patients. There was a technical success of 98.9% with 12,254 carotid arteries treated. Complications that occurred during the carotid stent placement or within a 30-day period following placement were recorded. Overall, there was transient ischemic attack rate of 3.07%, minor strokes of 2.14%, major strokes of 1.20%, and procedure-related deaths of 0.64%. The combined minor and major strokes and procedure-related death rate was 3.98% based on procedure number. With nonprocedure-related death rate of 0.77%, the total stroke and death rate was 4.75%. Subsets of questions were directed at the new use of distal embolic protection devices; there were 6,753 cases done without protection and which incurred a 5.29% rate of strokes and procedure-related deaths. In the 4,221 cases with cerebral protection, there was a 2.23% rate of strokes and procedure-related deaths. Restenosis rates of carotid stenting have been 2.7%, 2.6%, and 2.4% at 1, 2, and 3 years, respectively. The rate of neurologic events after stent placement has been 1.2%, 1.3%, and 1.7% at 1, 2, and 3 years, respectively. Endovascular stent treatment of carotid artery atherosclerotic disease is growing as an alternative for vascular surgery, especially for patients who are high risk for standard carotid endarterectomy. The periprocedure risks for major and minor strokes and death are generally acceptable at this early stage of development and have shown an improvement with technological developments, including distal embolic protection. Catheter Cardiovasc Interv 2003;60:259-266

486 citations

Performance
Metrics
No. of papers from the Journal in previous years
YearPapers
2023222
2022499
2021848
2020631
2019512
2018562